Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.130
Filtrar
1.
Heliyon ; 10(8): e29594, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38665570

RESUMO

The internal arc represents an unintentional release of electrical energy within the switchgear industry. Manufacturers must address this electro-thermal issue in their switchgears. Over the past decades, various researchers and engineering groups have examined the internal arc pressure rise in switchgears to mitigate damages. The high variability in pressure rise among switchgears due to diverse factors such as design, manufacturing, and electrical parameters results in varying reported pressure increases. This issue motivates the application of artificial intelligence (AI) in interpreting internal arc modeling. The present paper explores the impact of manufacturing parameters such as total duct width (TDW), height (H), and ducts condition (DC), along with environmental parameters like initial pressure (IP) and initial temperature (IT), on the maximum pressure (MP) generated during an internal arc in a medium voltage (MV) switchgear. For this purpose, 54 different computational fluid dynamics (CFD) models were built using the parameters indicated. An extreme gradient boosting (XGBoost) machine learning (ML) model was trained using different CFD models, with MP serving as the target variable for the ML model. The obtained results reveal a variation in the MP of the internal arc under the mentioned parameters, ranging from 17835.45 Pa to 144423.2 Pa. Using SHAP data revealed that IP, TDW, and DC were the most significant factors affecting the pressure increase of the internal arc phenomena.

2.
Heliyon ; 10(8): e28998, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38644884

RESUMO

The primary issues in the Himalayan Rivers are sediment and cavitation degradation of the hydroelectric power turbine components. During the monsoon season, heavy material is transported by streams in hilly areas like the Himalayas through regular rainfalls, glacial and sub-glacial hydrological activity, and other factors. The severe erosion of hydraulic turbines caused by silt abrasion in these areas requires hydropower facilities to be regularly shut down for maintenance, affecting the plant's overall efficiency. This article provides an in-depth examination of the challenges that can lead to cavitation, silt erosion, and a decrease in the efficiency of various hydroelectric turbines, and it demands attention on the design, manufacture, operation, and maintenance of the turbines. This study's main objective is to critically evaluate earlier theoretical, experimental, and numerical evaluation-based studies (on cavitation and silt erosion) that are provided and addressed throughout the study. As a part of this study, various strategies for mitigating the effects of these problems and elongating the time that turbine may be utilized before they must be replaced have been provided.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38668927

RESUMO

Repaired Tetralogy of Fallot (rTOF) patients suffer from pulmonary regurgitation and may require pulmonary valve replacement (PVR). Cardiac magnetic resonance imaging (cMRI) guides therapy, but conventional measurements do not quantify the intracardiac flow effects from pulmonary regurgitation or PVR. This study investigates intracardiac flow parameters of the right ventricle (RV) of rTOF by computational fluid dynamics (CFD). cMRI of rTOF patients and controls were retrospectively included. Feature-tracking captured RV endocardial contours from long-axis/short-axis cine. Ventricular motion was reconstructed via diffeomorphic mapping, serving as domain boundary for CFD simulations. Vorticity (1/s), viscous energy loss (ELoss, mJ/L) and turbulent kinetic energy (TKE, mJ/L) were quantified in RV outflow tract (RVOT) and RV inflow. These parameters were normalized against total RV kinetic energy (KE) and RV inflow vorticity to derive dimensionless metrics. Vorticity contours by Q-criterion were qualitatively compared. rTOF patients (n = 15) had mean regurgitant fraction 38 ± 12% and RV size 162 ± 35 mL/m2. Compared to controls (n = 12), rTOF had increased RVOT vorticity (142.6 ± 75.6/s vs. 40.4 ± 11.8/s, p < 0.0001), Eloss (55.6 ± 42.5 vs. 5.2 ± 4.4 mJ/L, p = 0.0004), and TKE (5.7 ± 5.9 vs. 0.84 ± 0.46 mJ/L, p = 0.0003). After PVR, there was decrease in normalized RVOT Eloss/TKE (p = 0.0009, p = 0.029) and increase in normalized tricuspid inflow vorticity/KE (p = 0.0136, p = 0.043), corresponding to reorganization of the "donut"-shaped tricuspid ring-vortex. The intracardiac flow in rTOF patients can be simulated to determine the impact of PVR and improve the clinical indications guided by cardiac imaging.

4.
Mol Pharm ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639477

RESUMO

The dissolution testing method described in the United States Pharmacopeia (USP) Chapter ⟨711⟩ is widely used for assessing the release of active pharmaceutical ingredients from solid dosage forms. However, extensive use over the years has revealed certain issues, including high experimental intervariability observed in specific formulations and the settling of particles in the dead zone of the vessel. To address these concerns and gain a comprehensive understanding of the hydrodynamic conditions within the USP 2 apparatus, computational fluid dynamic simulations have been employed in this study. The base design employed in this study is the 900 mL USP 2 vessel along with a paddle stirrer at a 50 rpm rotational speed. Additionally, alternative stirrer designs, including the hydrofoil, pitched blade, and Rushton impeller, are investigated. A comparison is also made between a flat-bottom tank and the USP round-bottom vessel of the same volume and diameter. Furthermore, this work examines the impact of various parameters, such as clearance distance (distance between the bottom of the impeller and bottom of the vessel), number of impeller blades, impeller diameter, and impeller attachment angle. The volume-average shear rate (Stv), fluid velocity (Utv), and energy dissipation rates (ϵtv) represent the key properties evaluated in this study. Comparing the USP2 design and systems with the same stirrer but flat-bottom vessel reveals more homogeneous mixing compared to the USP2 design. Analyzing fluid flow streamlines in different designs demonstrates that hydrofoil stirrers generate more suspension or upward movement of fluid compared to paddle stirrers. Therefore, when impellers are of a similar size, hydrofoil designs generate higher fluid velocities in the coning area. Furthermore, the angle of blade attachment to the hub influences the fluid velocity in the coning area in a way that the 60° angle design generates more suspension than the 45° angle design. The findings indicate that the paddle stirrer design leads to a heterogeneous shear rate and velocity distributions within the vessel compared with the other designs, suggesting suboptimal performance. These insights provide valuable guidance for the development of improved in vitro dissolution testing devices, emphasizing the importance of optimized design considerations to minimize hydrodynamic variability, enhance dissolution characterization, and reduce variability in dissolution test results. Ultimately, such advancements hold potential for improving in vitro-in vivo correlations in drug development.

6.
Heliyon ; 10(8): e29253, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38644843

RESUMO

The cigarette filter is an essential component of modern cigarettes and studying the flow distribution within the cigarette filter is of great significance in reducing the harm of cigarettes and optimizing smoking sensations. As the object of numerical simulation research, a three-dimensional model of the cigarette was accurately constructed through micro-CT reverse engineering, achieving a scanning accuracy of 4.05 µm. An overall porous media model of the cigarette filter was established to characterize the pressure distribution inside the filter. Based on the three-dimensional reconstruction, a local simulation model of the cavity-filtered filter was created by extracting a 1/36 geometric model. The simulation results of the overall porous media model of the cigarette filter were used as the pressure boundary conditions for the local simulation model of the cavity-filtered filter, and the effects of the wrapped paper and cavity on the flow field were analyzed. The results show that the simulated pressure drop in the overall porous media model of the cigarette filter had a deviation of less than 3.5% compared to the experimental results. This suggests that the porous media model can effectively predict the changes in pressure drop within the filter. When both wrapped paper and cavity were present, the velocity at the interface between acetate fiber and wrapped paper increased by 141.54%, while the pressure approached 0 Pa. Similarly, at the interface between acetate fiber and cavity, the velocity increased by 130.77%. It indicates that both wrapped paper and cavity significantly influenced the flow field characteristics within the cigarette filter. Additionally, as the porosity of the wrapped paper gradually increased from 0.69 to 0.99 in the radial direction, the fluid velocity increased by 14.46%, while the fluid pressure decreased by 29.09%. These changes were particularly evident when the porosity was below 0.87.

7.
Int J Numer Method Biomed Eng ; : e3825, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629309

RESUMO

Atrial fibrillation (AF) poses a significant risk of stroke due to thrombus formation, which primarily occurs in the left atrial appendage (LAA). Medical image-based computational fluid dynamics (CFD) simulations can provide valuable insight into patient-specific hemodynamics and could potentially enhance personalized assessment of thrombus risk. However, the importance of accurately representing the left atrial (LA) wall dynamics has not been fully resolved. In this study, we compared four modeling scenarios; rigid walls, a generic wall motion based on a reference motion, a semi-generic wall motion based on patient-specific motion, and patient-specific wall motion based on medical images. We considered a LA geometry acquired from 4D computed tomography during AF, systematically performed convergence tests to assess the numerical accuracy of our solution strategy, and quantified the differences between the four approaches. The results revealed that wall motion had no discernible impact on LA cavity hemodynamics, nor on the markers that indicate thrombus formation. However, the flow patterns within the LAA deviated significantly in the rigid model, indicating that the assumption of rigid walls may lead to errors in the estimated risk factors. In contrast, the generic, semi-generic, and patient-specific cases were qualitatively similar. The results highlight the crucial role of wall motion on hemodynamics and predictors of thrombus formation, and also demonstrate the potential of using a generic motion model as a surrogate for the more complex patient-specific motion. While the present study considered a single case, the employed CFD framework is entirely open-source and designed for adaptability, allowing for integration of additional models and generic motions.

8.
Comput Methods Programs Biomed ; 249: 108144, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38569255

RESUMO

OBJECTIVE: Iatrogenic coronary artery dissection is a complication of coronary intimal injury and dissection due to improper catheter manipulation. The impact of tear direction on the prognosis of coronary artery dissection (CAD) remains unclear. This study examines the hemodynamic effects of different tear directions (transverse and longitudinal) of CAD and evaluates the risk of thrombosis, rupture and further dilatation of CAD. METHODS: Two types of CAD models (Type I: transverse tear, Type II: longitudinal tear) were reconstructed from the aorto-coronary CTA dataset of 8 healthy cases. Four WSS-based indicators were analyzed, including time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and cross flow index (CFI). A thrombus growth model was also introduced to predict the trend of thrombus growth in CAD with two different tear directions. RESULTS: For most of the WSS-based indicators, including TAWSS, RRT, and CFI, no statistically significant differences were observed across the CAD models with varying tear directions, except for OSI, where a significant difference was noted (p < 0.05). Meanwhile, in terms of thrombus growth, the thrombus growing at the tear of the Type I (transverse tear) CAD model extended into the true lumen earlier than that of the Type II (longitudinal tear) model. CONCLUSIONS: Numerical simulations suggest that: (1) The CAD with transverse tear have a high risk of further tearing of the dissection at the distal end of the tear. (2) The CAD with longitudinal tear create a hemodynamic environment characterized by low TAWSS and high OSI in the false lumen, which may additionally increase the risk of vessel wall injury. (3) The CAD with transverse tear may have a higher risk of thrombosis and coronary obstruction and myocardial ischemia in the early phase of the dissection.


Assuntos
Dissecção Aórtica , Trombose , Humanos , Vasos Coronários/diagnóstico por imagem , Modelos Cardiovasculares , Hemodinâmica , Doença Crônica , Trombose/etiologia , Estresse Mecânico
9.
J Biotechnol ; 387: 79-88, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38582408

RESUMO

Among all the operating parameters that control the cell culture environment inside bioreactors, appropriate mixing and aeration are crucial to ensure sufficient oxygen supply, homogeneous mixing, and CO2 stripping. A model-based manufacturing facility fit approach was applied to define agitation and bottom air flow rates during the process scale-up from laboratory to manufacturing, of which computational fluid dynamics (CFD) was the core modeling tool. The realizable k-ε turbulent dispersed Eulerian gas-liquid flow model was established and validated using experimental values for the volumetric oxygen transfer coefficient (kLa). Model validation defined the process operating parameter ranges for application of the model, identified mixing issues (e.g., impeller flooding, dissolved oxygen gradients, etc.) and the impact of antifoam on kLa. Using the CFD simulation results as inputs to the models for oxygen demand, gas entrance velocity, and CO2 stripping aided in the design of the agitation and bottom air flow rates needed to meet cellular oxygen demand, control CO2 levels, mitigate risks for cell damage due to shear, foaming, as well as fire hazards due to high O2 levels in the bioreactor gas outlet. The recommended operating conditions led to the completion of five manufacturing runs with a 100% success rate. This model-based approach achieved a seamless scale-up and reduced the required number of at-scale development batches, resulting in cost and time savings of a cell culture commercialization process.

10.
Sci Total Environ ; 928: 172363, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38614342

RESUMO

There are a large number of airplanes currently being operated, in which the ventilation system needs to be improved to more effectively remove air contaminants. A potential approach is to adjust the supply air directions with the use of simple airflow deflectors. This study proposed a method for optimizing the supply air direction of ventilation in aircraft cabins based on the Re-field synergy index and Bayesian optimization. A validated numerical model was used to calculate the air distribution and air contaminant transport in a single-row single-aisle aircraft cabin to obtain the Re-field synergy values. The Bayesian optimization approach was used to identify the supply air direction which maximizes the Re-field synergy, namely, maximizes the mass transfer effectiveness. Finally, the air contaminant transport in a 7-row single-aisle aircraft cabin with the optimized supply air direction was evaluated to demonstrate the enhancement of ventilation performance. The results show that the proposed method based on the Re-field synergy index and Bayesian optimization can efficiently optimize the supply air direction in order to enhance the air contaminant removal in aircraft cabins. In the 7-row single-aisle aircraft cabin, the optimized supply air direction can reduce the average air contaminant concentration in the breathing zone of the passengers by up to 23 %.

11.
J Biomech ; 167: 112086, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38615481

RESUMO

Accurate assessment of portacaval pressure gradient (PCG) in patients with portal hypertension (PH) is of great significance both for diagnosis and treatment. This study aims to develop a noninvasive method for assessing PCG in PH patients and evaluate its accuracy and effectiveness. This study recruited 37 PH patients treated with transjugular intrahepatic portosystemic shunt (TIPS). computed tomography angiography was used to create three dimension (3D) models of each patient before and after TIPS. Doppler ultrasound examinations were conducted to obtain the patient's portal vein flow (or splenic vein and superior mesenteric vein). Using computational fluid dynamics (CFD) simulation, the patient's pre-TIPS and post-TIPS PCG was determined by the 3D models and ultrasound measurements. The accuracy of these noninvasive results was then compared to clinical invasive measurements. The results showed a strong linear correlation between the PCG simulated by CFD and the clinical invasive measurements both before and after TIPS (R2 = 0.998, P < 0.001 and R2 = 0.959, P < 0.001). The evaluation accuracy of this noninvasive method reached 94 %, and the influence of ultrasound result errors on the numerical accuracy was found to be marginal if the error was less than 20 %. Furthermore, the information about the hemodynamic environment in the portal system was obtained by this numerical method. Spiral flow patterns were observed in the portal vein of some patients. In a conclusion, this study proposes a noninvasive numerical method for assessing PCG in PH patients before and after TIPS. This method can assist doctors in accurately diagnosing patients and selecting appropriate treatment plans. Additionally, it can be used to further investigate potential biomechanical causes of complications related to TIPS in the future.


Assuntos
Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Hidrodinâmica , Veia Porta/diagnóstico por imagem , Hipertensão Portal/diagnóstico por imagem , Hemodinâmica
12.
Int J Numer Method Biomed Eng ; : e3822, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566253

RESUMO

We examined the effect of minimal lumen segmentation uncertainty on Fractional Flow Reserve obtained from Coronary Computed Tomography Angiography FFR CT $$ \left({\mathrm{FFR}}_{\mathrm{CT}}\right) $$ . A total of 14 patient-specific coronary models with different stenosis locations and degrees of severity were enrolled in this study. The optimal segmented coronary lumens were disturbed using intra ± 6 % $$ \left(\pm 6\%\right) $$ and inter-operator ± 15 % $$ \left(\pm 15\%\right) $$ variations on the segmentation threshold. FFR CT $$ {\mathrm{FFR}}_{\mathrm{CT}} $$ was evaluated in each case by 3D-OD CFD simulations. The findings suggest that the sensitivity of FFR CT $$ {\mathrm{FFR}}_{\mathrm{CT}} $$ to this type of uncertainty increases distally and with the stenosis severity. Cases with moderate or severe distal coronary lesions should undergo either exact and thorough segmentation operations or invasive FFR measurements, particularly if the FFR CT $$ {\mathrm{FFR}}_{\mathrm{CT}} $$ is close to the cutoff (0.80). Therefore, we conclude that it is crucial to consider the lesion's location and degree of severity when evaluating FFR CT $$ {\mathrm{FFR}}_{\mathrm{CT}} $$ results.

13.
R Soc Open Sci ; 11(4): 231453, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38577213

RESUMO

We present a non-iterative algorithm, FloatStepper, for coupling the motion of a rigid body and an incompressible fluid in computational fluid dynamics (CFD) simulations. The purpose of the algorithm is to remove the so-called added mass instability problem, which may arise when a light, floating body interacts with a heavy fluid. The idea underlying the presented coupling method is to precede every computational time step by a series of prescribed probe body motions in which the fluid response is determined, thus revealing the decomposition of the net force and torque into two components: (i) an added mass contribution proportional to the instantaneous body acceleration and (ii) all other forces and torques. The algorithm is implemented and released as an open-source extension module to the widely used CFD toolbox, OpenFOAM, as an alternative to the existing body motion solvers. The accuracy of the algorithm is investigated with several single-phase and two-phase flow benchmark cases. The benchmarks demonstrate excellent stability properties, allowing simulations even with massless bodies. They also highlight aspects of the implementation, such as the mesh motion method, where it can be improved to further enhance the flexibility and predictive capabilities of the code.

14.
J Endovasc Ther ; : 15266028241241494, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561992

RESUMO

OBJECTIVE: To identify risk factors for in-stent restenosis (ISR) in patients undergoing stent placement for superior mesenteric artery dissection (SMAD) and to determine the hemodynamic mechanism underlying ISR. METHODS: For this retrospective study, patients with SMAD who had ISR after stent placement were included in the ISR group, and age- and sex-matched patients with SMAD who did not experience ISR after stent placement were included in the control group. Clinical, imaging, and hemodynamic data were assessed. Multivariable regression was used to identify independent ISR risk factors. Structural and fluid dynamics simulations were applied to determine the hemodynamic mechanism underlying the occurrence of ISR. RESULTS: The study population included 26 patients with ISR and 26 control patients. Multivariate analysis demonstrated that stent-to-vascular (S/V) ratio (odds ratio [OR], 1.14; 95% confidence interval [CI]: 1.00-1.29; p=0.045), stent proximal position >10 mm away from the SMA root (OR, 108.67; 95% CI: 3.09-3816.42; p=0.010), and high oscillatory shear index (OSI) area (OR, 1.25; 95% CI: 1.02-1.52; p=0.029) were predictors of ISR. In structural and fluid dynamics simulations, a stent proximal position near the abdominal aorta (AA) or entering into the AA reduced the contact area between the proximal struts of the stent and the vascular wall, and alleviated the distal lumen overdilation. CONCLUSION: The S/V ratio, stent proximal position away from the SMA root (>10 mm), and high OSI area are independent risk factors for ISR in patients with SMAD undergoing stent placement. Deploying the proximal end of the stent near the AA or entering into the AA appears to improve the hemodynamic environment in the SMA lumen and ultimately reduce the risk of ISR. CLINICAL IMPACT: In-stent restenosis is an uncommon but potentially catastrophic complication after stent placement for the management of superior mesenteric artery dissection. This study identified risk factors for in-stent restenosis and demonstrated that, as long as the stent can fully cover the dissection range, deploying the proximal end of the stent near the abdominal aorta or less entering into the abdominal aorta may reduce the risk of in-stent restenosis in this patient population.

15.
J Biomech ; 168: 112111, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38657433

RESUMO

Snoring is common in children and is associated with many adverse consequences. One must study the relationships between pharyngeal morphology and snoring physics to understand snoring progression. Although some model studies have provided fluid-structure interaction dynamic descriptions for the correlation between airway size and snoring physics, the descriptions still need to be further investigated in patient-specific airway models. Fluid-structure interaction studies using patient-specific airway structures complement the above model studies. Based on reported cephalometric measurement methods, this study quantified and preset the size of the palatopharynx airway in a patient-specific airway and investigated how the palatopharynx size affects the pharyngeal airflow fluctuation, soft palate vibration, and glossopharynx vibration with the help of a verified FSI method. The results showed that the stenosis anterior airway of the soft palate increased airway resistance and airway resistance fluctuations, which can lead to increased sleep effort and frequent snoring. Widening of the anterior airway can reduce airflow resistance and avoid obstructing the anterior airway by the soft palate vibration. The pharyngeal airflow resistance, mouth inflow proportion, and soft palate apex displacement have components at the same frequencies in all airway models, and the glossopharynx vibration and instantaneous inflow rate have components at the same frequencies, too. The mechanism of this same frequency fluctuation phenomenon can be explained by the fluid-structure interaction dynamics of an ideal coupled model consisting of a flexible plate model and a collapsible tube model. The results of this study demonstrate the potential of FSI in studying snoring physics and clarify to some degree the mechanism of airway morphology affecting airway vibration physics.

16.
Respir Physiol Neurobiol ; : 104265, 2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38653435

RESUMO

Obstructive Sleep Apnea Syndrome (OSAS) disrupts millions of lives with its burden of airway obstruction during sleep. Continuous Positive Airway Pressure (CPAP) therapy has been scrutinized for its biomechanical impact on the respiratory tract. This study leverages computational fluid dynamics to investigate CPAP's effects at 9cm H2O (882.6Pa) on the computed-tomography-based nasal-to-14-generation full respiratory tract model compared to ambient conditions, focusing on static pressure, airflow velocity, and shear stress. Our findings reveal that CPAP significantly increases static pressure, enhancing airway patency without adverse changes in airflow velocity or harmful shear stress on lung tissue, challenging prior concerns about its safety. Notably, the larynx experiences the highest shear stress due to its narrow anatomy, yet CPAP therapy overall supports airway walls against collapse. This investigation highlights CPAP's critical role in OSAS treatment, offering reassurance about its safety and efficacy. By clarifying CPAP therapy's physiological impacts, our study contributes vital insights for optimizing OSAS management strategies, affirming CPAP's benefit in maintaining open airways with minimal tissue strain.

17.
J Neurosurg Case Lessons ; 7(16)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38621304

RESUMO

BACKGROUND: Silent magnetic resonance angiography (MRA) mitigates metal artifacts, facilitating clear visualization of neck remnants after stent and coil embolization of cerebral aneurysms. This study aims to scrutinize hemodynamics at the neck remnant by employing silent MRA and computational fluid dynamics. OBSERVATIONS: The authors longitudinally tracked images of a partially thrombosed anterior communicating artery aneurysm's neck remnant, which had been treated with stent-assisted coil embolization, using silent MRA over a decade. Computational fluid dynamics delineated the neck remnant's reduction process, evaluating hemodynamic parameters such as flow rate, wall shear stress magnitude and vector, and streamlines. The neck remnant exhibited diminishing surface area, volume, neck size, dome depth, and aspect ratio. Its reduction correlated with a decline in the flow rate ratio of the remnant dome to the inflow parent artery. Analysis delineated regions within the contracting neck remnant characterized by consistently low average wall shear stress magnitude and variation, accompanied by notable variations in wall shear stress vector directionality. LESSONS: Evaluation of neck remnants after stent-coil embolization is possible through silent MRA and computational fluid dynamics. Predicting the neck remnant reduction may be achievable through hemodynamic parameter analysis.

18.
Sci Rep ; 14(1): 8476, 2024 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605063

RESUMO

Computational fluid dynamics (CFD) has been utilized to calculate hemodynamic parameters in anterior communicating artery aneurysm (AComA), which is located at a junction between left and right A1 and A2 segments. However, complete or half circle of Willis (CoW) models are used indiscriminately. This study aims to suggest recommendations for determining suitable CoW model. Five patient-specific CoW models with AComA were used, and each model was divided into complete, left-half, and right-half models. After validating the CFD using a flow experiment, the hemodynamic parameters and flow patterns in five AComAs were compared. In four out of five cases, inflow from one A1 side had a dominant influence on the AComA, while both left and right A1 sides affected the AComA in the remaining case. Also, the average difference in time-averaged wall shear stress between the complete and half models for four cases was 4.6%, but it was 62% in the other case. The differences in the vascular resistances of left and right A1 and A2 segments greatly influenced the flow patterns in the AComA. These results may help to enhance clinicians' understanding of blood flow in the brain, leading to improvements in diagnosis and treatment of cerebral aneurysms.


Assuntos
Aneurisma Intracraniano , Humanos , Círculo Arterial do Cérebro , Hemodinâmica/fisiologia , Circulação Cerebrovascular/fisiologia , Encéfalo
19.
Heliyon ; 10(8): e29309, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38628761

RESUMO

This study conducts a numerical comparison of the thermal performance of three distinct working fluids (pure water, TiO2, and SiO2 water-based nanofluids) within an evacuated tube solar collector using Computational Fluid Dynamics. The study evaluates thermohydraulic performance alongside global and local entropy generation rates, while considering variations in solar radiation values and inlet mass flow rates. Results indicate that nanofluids demonstrate superior performance under low solar radiation, exhibiting higher outlet temperatures, velocities, thermal efficiency, and exergy efficiency compared to pure water. However, at the higher solar radiation level, the efficiency of SiO2 water-based nanofluid diminishes due to its impact on specific heat. Furthermore, the entropy generation analysis reveals significant reductions with TiO2 water-based nanofluid in all the phenomena considered (up to 79 %). The SiO2 nanofluid performance aligns closely with pure water under high radiation value. This investigation offers valuable insights into the utilization of nanofluids in solar collectors across diverse operating conditions, emphasizing their pivotal role in enhancing overall performance.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38592600

RESUMO

The blood protein Von Willebrand factor (VWF) is critical in facilitating arterial thrombosis. At pathologically high shear rates, the protein unfolds and binds to the arterial wall, enabling the rapid deposition of platelets from the blood. We present a novel continuum model for VWF dynamics in flow based on a modified viscoelastic fluid model that incorporates a single constitutive relation to describe the propensity of VWF to unfold as a function of the scalar shear rate. Using experimental data of VWF unfolding in pure shear flow, we fix the parameters for VWF's unfolding propensity and the maximum VWF length, so that the protein is half unfolded at a shear rate of approximately 5000 s - 1 . We then use the theoretical model to predict VWF's behaviour in two complex flows where experimental data are challenging to obtain: pure elongational flow and stenotic arterial flow. In pure elongational flow, our model predicts that VWF is 50% unfolded at approximately 2000 s - 1 , matching the established hypothesis that VWF unfolds at lower shear rates in elongational flow than in shear flow. We demonstrate the sensitivity of this elongational flow prediction to the value of maximum VWF length used in the model, which varies significantly across experimental studies, predicting that VWF can unfold between 2000 and 3200 s - 1 depending on the selected value. Finally, we examine VWF dynamics in a range of idealised arterial stenoses, predicting the relative extension of VWF in elongational flow structures in the centre of the artery compared to high shear regions near the arterial walls.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...